14
CONTROL & FEATURES
Voltage Selector Switch
Switch Position
AC Circuit Protectors
120/240V:
120V ONLY:
ACCIRCUIT PROTEC TOR
PUSH
ON
VOLTAGESELECTOR SWITCH
CIRCUITPROTECTO R
forReceptacle
CIRCUITPROTECTO R
forReceptacle
CIRCUITPROTECTO R
forReceptacle
120V30A
120/240V30A
OFF
120V20A
120V/240V
120VONLY
CIRCUITPROTECTO R
forReceptacle
120V20A
The AC circuit protectors will automatically switch OFF if there is a
short circuit or a significant overload of the generator at each
receptacle. If an AC circuit protector switches OFF automatically, check
that the appliance is working properlyand does not exceed the rated
load capacity of the circuit before resetting the AC circuit protector ON.
Select the voltage before starting the engine.
The 120V and 120/240V receptacles can be used
simultaneously.
ONLY the 120V receptacles can be used. Donot use the
120/240V receptacle in this position. The most power will be available
at the 30A 120V locking plug receptacle.
The voltage selector switch changes generator output to produce
‘‘120V ONLY’’ or ‘‘120/240V’’. If a 240V appliance is connected to the 4-
prong receptacle, the switch must be in the ‘‘120/240V’’ position. If
only the 120V 3-prong receptacles are being used,select the ‘‘120V
ONLY’’ position.
08/02/05 13:48:02 31Z25600_015