OPERATION
AC OPERATION
120V/240V
120VONLY
VOLTAGESELECTOR SWITCH
OUTPUT
INDICATOR
(GREEN)
OVERLOAD
INDICATOR
(RED)
If an appliance begins to operate abnormally, becomes sluggish, or
stops suddenly, turn it off immediately. Disconnect the appliance, and
determine whether the problemis in the appliance or the rated load
capacity of the generator has been exceeded.
Turn the voltage selector switch to either position.
With the voltage selector switch in the ‘‘120/240V’’ position, you can
use the 120V and 120/240V receptacles simultaneously. If you are
NOT using the 120/240V receptacle but require more power fromthe
120V locking plug receptacle, then select the ‘‘120V ONLY’’position.
Substantial overloading that continuously lights the overload indicator(red) may damage the generator.Marginal overloading thattemporarily lights the overload indicator(red) may shorten the servicelife of the generator.
Start the engine and make
sure the output indicator
(green) comes on.
1.
2.