TRANSPORTING/STORAGE
Transporting
Always turn the fuel valve off when transport-
ing the tiller.
Keep it level to avoid fuel and oil leakage, and
secure it with a suitable strap or rope.
Preparation For Storage
(Over 30 days):
l
Close the IN. & EX. valves and the contact
breaker points.
Pull the starter handle until it becomes hard to
pull (the piston is coming up on the compression
stroke).
Both valves and the contact breaker points will
be closed. This will protect the valve seats and
the points from corrosion.
l
Drain the gasoline from the fuel tank and car-
buretor:
Remove the fuel line from the fuel valve, turn
the valve ON and dram all gasoline from the fuel
tank into metal container.
Remove the carburetor darin bolt to dram
gasoline from carburetor. Reinstall the fuel line
and tighten the dram bolt securely. Turn the fuel
valve OFF.
B Gasoline is flnmmable and explosive
under certain conditions. Do not smoke or allow
flames or sparks near the equipment while draining
fuel.
24
(1) Carburetor drain bolt