Safety interlock system
m Before inspecting, ensure that the area in front of and behind
the tractor is clear of people, pets and obstacles.
This tractor is equipped with a series of inhibitor switches which prevent
the engine from being started unless the proper operating procedures are
followed. Observe the following procedures to check the inhibitor
switches.
m Do not operate the tractor if there are any abnormalities in the
system, or in the operation of the switches. An accident or severe per-
sonal injury could result.
Consult your authorized Honda tractor dealer.
To check the system, sit in the seat, and lock the parking brake.
To prevent accidental engine start up, be sure to remove the spark plug
caps from the spark plugs when performing the inspection procedures I to
3.
- I. Neutral switch
(I 1 Move the front and rear
P.T.O. levers to the OFF
position.
OFF OFF 1 OR2
(2) Place the main transmission
lever in āIā or ā2.ā
(3) Depress the brake pedal
enough to release the park-
ing brake.
(4) With the brake pedal and
clutch pedal held down,
turn the engine switch (igni-
tion switch) key to START.
The starter should not
operate.
(5) Put the main transmission
lever into NEUTRAL.
(6) Return the engine switch
(ignition switch) key to
OFF.
43