7 Data, 2 Stop, Parity Space8 Data, 1 Stop, Parity Space7 Data, 1 Stop, Parity Mark7 Data, 2 Stop, Parity Mark8 Data, 1 Stop Parity MarkRS232 Handshaking

RS232 Handshaking allows control of data transmission from the scanner using software commands from the host device. When RTS/CTS is turned Off, no data flow control is used.

Flow Control, No Timeout: The scanner asserts RTS when it has data to send, and will wait indefinitely for CTS to be asserted by the host.

Character-Based Flow Control, No Timeout: The scanner asserts RTS when it has a character to send, and will wait indefinitely for CTS to be asserted by the host

Two-Direction Flow Control: the host to transmit. The host transmit.

The scanner asserts RTS when it is OK for asserts CTS when it is OK for the device to

Flow Control with Timeout: The scanner asserts RTS when it has data to send and waits for a delay (see RS232 Timeout on page 2-22)for CTS to be asserted by the host. If the delay time expires and CTS is not asserted, the device transmit buffer is cleared and scanning may resume.

Character-Based Flow Control with Timeout: The scanner asserts RTS when it has a character to send and waits for a delay (see RS232 Timeout on page 2-22)for CTS to be asserted by the host. If the delay time expires

2 - 21