3 - 3

Good Read Delay
This sets the minimum amount of time before the imager can read another bar
code.

Default = No Delay.

User-Specified Good Read Delay

If you want to set your own length for the good read delay, scan the bar code
below, then set the delay (from 0-30,000 milliseconds) by scanning digits from
the inside back cover, then scanning

Save

.
Trig ger Mode s

Manual/Serial Trigger

You can activate the imager either by pressing the trigger, or using a serial trig-
ger command (see Trigger Commandson page 11-4). When in manual tr igger
mode, the imager scans until a bar code is read, or until the trigger is released.
When in serial mode, the imager scans until a bar code has been read or until
the deactivate command is sent. In serial mode, the imager can also be set to
turn itself off after a specified time has elapsed (see Read Time-Out, which fol-
lows).

Read Time-Out

Use this selection to set a time-out (in milliseconds) of the imager’s trigger when
using serial commands to trigger the imager. Once the imager has timed out,
you can activate the imager either by pressing the trigger or using a serial trig-
* No Delay
Short Delay (500 ms)
Medium Delay (1000 ms)
Long Delay (1500 ms)
User-Specified Good Read Delay
* Manual/Serial Trigger