EAS System Connection

The following information should be used in conjunction with the manufacturer’s documentation EAS system.

Checkpoint® EAS System Integration

Honeywell cables compatible with Checkpoint EAS systems include five additional wires for device connection*. Consult the table below for the appropriate wire and terminal configuration.

Antenna and InterlockConnection

Cable

 

Checkpoint Device

(MX-5S236-E-3 or MX-5S114-E-3)

 

 

 

 

 

 

Wire Color

Wire Gauge

Connection

Type

Solid Light Green

Thin

INTLK + Terminal

Interlock

Solid Black

Thin

INTLK - Terminal, GND

 

Red and White

Thick

Antenna + Terminal

 

Black and White

Thick

Antenna - Terminal

Antenna

No Insulation/Shield

 

Antenna Shield

 

† Interlock functionality requires specific EAS device settings. Consult the manufacturer’s EAS system documentation for the appropriate switch and timing potentiometer settings.

*Caution Statements For North America:

Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements of a NEC Class 2 power source or Limited Power Source as defined in UL 60950-1 2nd edition Clause 2.5.

For Other Countries:

Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements of a Limited Power Source as defined in IEC 60950-1 2nd edition Clause 2.5.

40