EAS System Connection
The following information should be used in conjunction with the manufacturer’s documentation EAS system.
Checkpoint® EAS System Integration
Honeywell cables compatible with Checkpoint EAS systems include five additional wires for device connection*. Consult the table below for the appropriate wire and terminal configuration.
Antenna and Interlock† Connection
Cable |
| Checkpoint Device | ||
|
| |||
|
|
|
| |
Wire Color | Wire Gauge | Connection | Type | |
Solid Light Green | Thin | INTLK + Terminal | Interlock† | |
Solid Black | Thin | INTLK - Terminal, GND | ||
| ||||
Red and White | Thick | Antenna + Terminal |
| |
Black and White | Thick | Antenna - Terminal | Antenna | |
No Insulation/Shield |
| Antenna Shield |
|
† Interlock functionality requires specific EAS device settings. Consult the manufacturer’s EAS system documentation for the appropriate switch and timing potentiometer settings.
*Caution Statements For North America:
Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements of a NEC Class 2 power source or Limited Power Source as defined in UL
For Other Countries:
Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements of a Limited Power Source as defined in IEC
40