Honeywell HE420A installation instructions Application, Installation, Select Location And Mount

Models: HE420A

1 8
Download 8 pages 54.14 Kb
Page 1
Image 1
READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

HE420A Steam Power Humidifier

INSTALLATION INSTRUCTIONS

APPLICATION

The HE420A Steam Power Humidifier uses a thermal fan interlock control to provide humidification for the whole house. The steam power humidifier is designed to work with high efficiency furnaces and heat pumps.

INSTALLATION

IMPORTANT

This product is for residential applications only and must be installed by a qualified HVAC con- tractor. Failure to comply could invalidate the product warranty, or result in serious injury or electrocution.

SELECT LOCATION AND MOUNT

HE420A Steam Power Humidifier WARNING

Electrocution, Heavy Equipment and Chemical Hazard.

Can cause death, blindness, water damage to home and heater failure.

Do not cut into any air conditioning or electrical line.

Wear safety glasses when cutting or drilling.

Mount the humidifier in a level position to avoid water damage and heater failure.

Reinforce duct as necessary to ensure stability.

There are three typical ways of mounting the steam humidifier. See Fig. 1, 2, and 3. Be sure to select a location where the humidifier can be plugged in without an extension cord. The preferred installation location is on the warm air side of the furnace. If that location is not possible, the humidifier should be mounted a minimum of 6 ft (1.8m) upstream from the furnace filter. Depending on the location selected, additional duct reinforcement may be necessary because the humidifier weighs 18 lb when filled with water.

M10536B

Fig. 1. Mount humidifier horizontally under duct

using mounting bracket.

M10578B

Fig. 2. Mount humidifier horizontally under duct.

69-1108-2
Page 1
Image 1
Honeywell HE420A installation instructions Application, Installation, Select Location And Mount, using mounting bracket