This heater is equipped with SureSetDigital Controls that provide the ability to set the temperature to the exact degree desired. To operate, simply follow these instructions.

S T E P 1 : P O W E R

Press the Power button ( S T E P 1 : P O W E R ) once to start the heater on High Power ( S T E P 2 : S E T T E M P E R A T U R ES T E P 3 : S E T T I M E R ), Continuous Run ( Manual background ) (Fig. 1). If left at this setting, the unit will run continuously on High Power (1500 watts, 12.5 amps) and will not shut off until the unit is manually turned off.

Press the Power button ( Manual background ) again to change to Low Power ( Manual background ), Continuous Run ( Manual background ). If left at this setting, the unit will run continuously on Low Power (900 watts, 7.5 amps) and will not shut off until the unit is manually turned off.

Press the Power button ( Manual background ) a third time to turn the heater OFF.

Fig. 1

Continuous Run Icon

NOTE: If operated at the Low setting, the heater will not provide as much heat output as in the High setting, however, the Low setting will not require as much electrical current to operate. To avoid overloading a circuit, do not plug the heater into a circuit that already has other appliances working.

S T E P 2 : S E T T E M P E R A T U R E

Press the Temp/Timer button ( Manual backgroundManual backgroundManual background ) until the Temperature Icon ( Manual background ) blinks. The current room temperature will appear (Fig. 2).

Use the Up and Down arrow buttons ( Manual backgroundManual background ) to set the Desired Temperature (Fig. 2).

The Temperature Icon ( Manual background ) will stop blinking and the current room temperature will reappear after the Desired Temperature is set.

The heater will turn off shortly after the Desired Temperature is reached and the Temperature Display will blink.

The heater will turn back on when the room temperature drops below the Desired Temperature. The Temperature Display will then stop blinking and will display the current room temperature.

S T E P 3 : S E T T I M E R

NOTE: This function should only be set if you desire that the heater be automatically shut off after a certain period of time (1 to 10 hours from the time the function is set). Always set the Desired Temperature prior to setting the Timer (see Step 2) so that the heater will shut off at the Desired Temperature setting and not run continuously.

Fig. 2

Temperature Icon

 

Fig. 3

Timer Icon

Auto Off Icon

Press the Temp/Timer button ( Manual backgroundManual backgroundManual background ) until the Timer Icon ( Manual backgroundManual background ) blinks. The Hour Display will appear. The Auto Off icon will also appear (Fig. 3).

Use the Up and Down arrow buttons ( Manual backgroundManual background ) to set the heater operation time between 1 and 10 hours (Fig. 3). Once the timer function is set the hour set will remain displayed until the time set runs out.

The heater will automatically turn off when time runs out.

NOTE: If the Desired Temperature was set prior to setting the Timer function, the heater will cycle on and off as per the selected Desired Temperature setting. To return to the Continuous Run Mode (Fig. 1), press