Honeywell PRO-2200 Wiring Diagram for Connectors 1 through, 1 2 3 4 1 2 3 4 5 6 7 8 9 1 2 3

Models: PRO-2200

1 20
Download 20 pages 9.1 Kb
Page 16
Image 16
Wiring Diagram for Connectors 1 through 7

16

Installation Guide

PRO-2200 Two Reader Module PRO22R2

Wiring Diagram for Connectors 1 through 7

Door

 

EOL

RED

Input 5

 

 

 

Status Switch

BLACK

Input 5 Common

 

 

 

WHITE

Input 6

Egress

 

 

GREEN

Input 6 Common

Push-Button

EOL

 

 

Switch

 

 

 

Input 1

 

 

 

 

Typical Connection

 

Input 1 Common

RED

 

 

 

 

Input 2

 

 

 

 

Input 2 Common

Door Lock

 

S-4

Relay 1 NO

 

 

 

Suppressor

Relay 1 C

 

 

 

 

 

 

 

BLACK

Relay 1 NC

 

 

 

 

Separate

 

 

 

Relay 2 NO

-

 

 

Relay 2 C

Power VDC

 

 

Relay 2 NC

Supply

+

 

 

 

RED

+5 or +12V DC Out

 

 

 

Voltage Is Selected By

BROWN

Red LED

Jumper J2 On Board

YELLOW

Beeper

 

 

 

KP-13

 

 

WHITE

Data-1

 

 

 

 

Weigand

 

GREEN

Data-0

Keypad

 

NC

BLACK

Common

 

 

 

DRAIN

 

 

 

 

Chassis GND

Input 3

 

 

 

Input 3 Common

 

 

 

Inside Panel

 

 

 

Input 4

 

 

 

 

Separate 1

2

Power VDC 3

4

Supply 1

2

 1 3

4

Two Reader Board 5

6

Short 7

8

1 9 Door Lock 10

Separate – 1

2

Proximity 3

4

( For Rack 5

6

4 1

2 3

Two Reader Board

D77

D73

Reader

 

D78

12V

5V

 

 

1

J2 - Reader1

VDC Select

 

 

D74

 

Short

Together*

1

2

3

1RS-485

2Power

3*Rack mount configuration

4Manual background

1

2

3

4

5

6

Door Lock

Separate

Power VDC

Supply +

Voltage Is Selected By Jumper J3 On Board

Proximity

Reader

CardRack

PWR & Com

Harness*

( For Rack

Mount Only )

 

RED

Input 4 Common

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S-4

Relay 3 NO

 

 

 

 

 

 

 

Suppressor

Relay 3 C

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK

 

 

 

Relay 3 NC

 

 

 

 

 

 

 

 

 

 

 

 

Relay 4 NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relay 4 C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relay 4 NC

 

 

 

 

 

RED

+5 or +12V DC Out

 

 

 

 

 

BROWN

Red LED

 

 

 

 

 

YELLOW

Beeper

 

 

 

 

 

WHITE

Data-1

 

 

 

 

 

GREEN

Data-0

 

 

 

 

 

BLACK

Common

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DRAIN

 

 

 

Chassis GND

 

 

 

485-Com +

 

Inside Panel

 

 

 

 

485-Com -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

485-Gnd

 

 

 

 

 

 

 

 

 

 

 

 

PWR +

 

 

 

 

 

 

 

 

 

 

 

 

PWR -

4

Manual background 5

6

Manual background 7

8

Manual background 9 Manual background 10

Manual background 1

2

Manual background 3

4

Manual background 5

6

Manual background 1

Manual background 2 Manual background 3

Manual background 1

2

 

D75

Configuration

 

 

 

Reader

 

 

Dip Switches

 

 

S1

 

 

1

12V

5V

2

3

 

2

J3 - Reader2

4

 

5

 

VDC Select

6

 

 

 

7

 

 

 

8

RS-485

 

D79

 

 

D80

 

 

 

 

 

J1 - RS485

 

Power

Termination

 

Jumper

 

 

 

*Rack mount configuration