T8611G CHRONOTHERM® IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS

Temperature Settings

Refer to Table 2 for the default program. If the daytime energy savings period is not used, press the period key (Leave or Return) until the time is blank. The fan setting feature is available on select thermostat models. See Owner’s Guide, form number 69-0940, for complete instructions on changing the program.

Table 2. Default Program Settings.

Period

Time

Heat

Cool

Fan

Setpoint

Setpoint

Setting

Wake

6:45 AM

20°C

25°C

Auto

 

 

(68°F)

(77°F)

 

Leave

8:45 AM

4.5°C

37°C

Auto

 

 

(40°F)

(99°F)

 

Return

5:00 PM

20°C

25°C

Auto

 

 

(68°F)

(77°F)

 

Sleep

10:00 PM

4.5°C

37°C

Auto

 

 

(40°F)

(99°F)

 

To change a setting, use the increase ! or decrease " key.

To scroll the Installer Setup numbers backward, press the Time key.

To exit the Installer Setup, press Run Program.

Wait

Set Program

 

Set Day/Time

Temporary

Setting

Em Heat

Recovery

 

 

 

 

AM

 

 

 

 

 

 

 

 

Off

Hold for

 

 

 

 

PM

 

 

Cool

 

 

 

 

 

 

 

 

 

Auto

Filter

 

 

 

 

 

 

 

 

 

 

Em Ht

 

Aux Ht

Days

 

 

 

 

 

 

 

 

 

Fan

Mon Tue Wed Thu Fri Sat Sun

Repl Batt Room

Outdoor

On

Wake Leave

 

Return

Sleep

DST

Heat Cool

Auto

M14559

Fig. 9. Display of all LCD segments.

INSTALLER SETUP

NOTE: For most applications, the thermostat factory- settings will not need to be changed. Review the factory settings in Table 2 and if no changes are necessary, go to the Installer System Test section.

The Installer Setup is used to customize the thermostat to specific systems. Some of the options include temperature display, changeover and outdoor temperature display. Installer Setup numbers are listed in Table 3. The table includes all the configuration options and the factory-settings for the T8611.

A combination of key presses is required to use the Installer Setup feature:

To enter the installer setup, press and hold the information i key with the increase ! and decrease " keys until the first number is displayed. All display segments appear for approximately three seconds before the number is displayed. See Fig. 9 and 10.

To advance to the next Installer Setup, press the Time key.

INSTALLER SETUP

FACTORY SETTING OR OTHER

NUMBER DISPLAY

CHOICE DISPLAY (COLUMN 3

(COLUMN 2 OF TABLE 3)

OR 5 OF TABLE 3)

 

M14618

Fig. 10. Display of Installer Setup

number and setting.

IMPORTANT

Only configurable numbers are shown on the device. Example: If thermostat does not have a system key, Installer Setup Number 12 will not be displayed. Review Table 3 factory-settings and mark any desired changes in the Actual Setting column. When Installer Setup is com- plete, review the settings to confirm that they match the system.

Table 3. Thermostat Installer Setup Options.

 

Installer Setup

Factory Setting

 

Other Choices

 

 

Number (Press

(Press ! or " key to change)

 

Select

Time key to

 

 

 

 

Actual

Display

Description

Display

Description

change)

Setting

Not Used.

1 thru 4

Heating cycle

5

6

Stage 2

1, 6 or 9

1—1 cph

 

rate.

 

 

 

 

6—6 cph used for last stage

 

 

 

 

 

 

of heat pump systems

 

 

 

 

 

 

9—9 cph used for electric

 

 

 

 

 

 

heat

 

 

6 (Not used)

 

 

 

 

 

 

 

 

 

7

6

Emergency heat

3, 6 or 9

 

 

 

 

 

 

 

 

 

Not Used.

8 thru 11

 

 

 

 

 

 

 

System setting

12

1

Manual

0 or 2

0—Auto changeover

 

adjustment

 

 

changeover

 

2—Fixed auto changeover

 

69-1406—1

4

Page 4
Image 4
Honeywell T8611G installation instructions Installer Setup, Temperature Settings