T8611G CHRONOTHERM® IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS

Table 3. Thermostat Installer Setup Options. (Continued)

 

Installer Setup

Factory Setting

 

Other Choices

 

 

Number (Press

(Press ! or " key to change)

 

Select

Time key to

 

 

 

 

 

Actual

Display

Description

Display

 

Description

change)

 

Setting

Temperature

37

0

No difference in

-3 thru 3

1—Display adjusts to 1°F

 

display

 

 

displayed

 

 

higher than actual room

 

adjustment.

 

 

temperature and

 

 

temperature.

 

 

 

 

actual room

 

2—Display adjusts to 2°F

 

 

 

 

temperature.

 

 

higher than actual room

 

 

 

 

 

 

 

temperature.

 

 

 

 

 

 

3—Display adjusts to 3°F

 

 

 

 

 

 

 

higher than actual room

 

 

 

 

 

 

 

temperature.

 

 

 

 

 

 

-1—Display adjusts to 1°F

 

 

 

 

 

 

 

lower than actual room

 

 

 

 

 

 

 

temperature.

 

 

 

 

 

 

-2—Display adjusts to 2°F

 

 

 

 

 

 

 

lower than actual room

 

 

 

 

 

 

 

temperature.

 

 

 

 

 

 

-3—Display adjusts to 3°F

 

 

 

 

 

 

 

lower than actual room

 

 

 

 

 

 

 

temperature.

 

Furnace Air

43

0

Off

1, 2, 3, 4

1

– 10 days

 

Filter Timer.

 

 

 

 

2

– 30 days

 

 

 

 

 

 

3

– 60 days

 

 

 

 

 

 

4

– 120 days

 

 

 

 

 

 

(Times counted when heat,

 

 

 

 

 

 

cool or fan is running.)

 

Humidifier Pad

44

0

Off

1, 2, 3

1

– 90 days

 

Monitor.

 

 

 

 

2

– 180 days

 

 

 

 

 

 

3

– 365 days

 

 

 

 

 

 

(Times counted by calendar

 

 

 

 

 

 

days in heat mode.)

 

Ultraviolet (UV)

45

0

Off

1

1

– 365 days

 

Air Treatment

 

 

 

 

(Times counted by calendar

 

System Lamp

 

 

 

 

days in any mode.)

 

Monitor.

 

 

 

 

 

 

 

IMPORTANT

 

 

 

 

 

 

 

Review the settings to confirm that they match the system. Press Run Program to exit the Installer Setup. The thermostat has saved the Installer Setup changes and initiated a reset in order to operate using the new settings. Be sure to set the current day and time immediately.

69-1406—1

6

Page 6
Image 6
Honeywell T8611G installation instructions Ultraviolet UV