T8775A,C THE DIGITAL ROUNDNON-PROGRAMMABLE THERMOSTATS

Rc

B

G

2

Y

R

W

 

COMPRESSOR

CONTACTOR

 

HEATING

FAN

1

RELAY OR

RELAY

 

VALVE COIL

 

1

FUEL SWITCH

M19497

Fig. 12. Fuel switch.

1POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.

2REMOVE FACTORY INSTALLED JUMPER BETWEEN R AND RC.

M19517

Fig. 10. Typical hookup of T8775C in heat-cool system

with two transformers.

4

 

O

 

B

 

Rc

2

G

Y 3

R

 

W

DIP Switch

To adjust the heat cycle rate or the Fahrenheit/Celsius temperature display, locate DIP switch 1, 2 and 3 on the back of the thermostat. See Fig. 13.

BACK OF THERMOSTAT

 

COMPRESSOR

 

HEAT

 

CHANGEOVER

 

CONTACTOR

 

 

VALVE

 

 

 

1

FAN

 

COOL

 

 

 

RELAY

CHANGEOVER

 

VALVE

 

 

 

1

POWER SUPPLY. PROVIDE DISCONNECT MEANS

 

AND OVERLOAD PROTECTION AS REQUIRED.

2

FACTORY INSTALLED JUMPER.

3

USE A JUMPER WIRE (NOT SUPPLIED) TO CONNECT W TO Y.

4

USE EITHER O OR B FOR HEAT PUMP CHANGEOVER.

 

 

 

M19516

Fig. 11. Typical hookup of T8775C in single-stage heat

pump system.

CUSTOMIZE THERMOSTAT

Setting Fuel Switch (T8775C only)

The fuel switch is preset at the factory in the F position. See Fig. 12. This is the correct setting for gas or oil systems. If the T8775C is being installed on an electric heat system, or a heat pump, set the switch to the E position. The E position allows the fan to turn on immediately with the heating equipment in a system where the G terminal is connected.

 

3

 

2

ON

1

M19567

DIP SWITCH

Fig. 13. DIP switch.

Set Heat Cycle Rate

Use DIP switches 1 and 2 to set the heat cycle rate. See Table 1.

Table 1. Heat Cycle Rate.

 

 

 

 

 

Cycles

DIP

DIP

Heating System

Per

Switch

Switch

Hour

1

2

Steam, Gravity

1

On

On

 

 

 

 

High Efficiency Warm Air (90%+

3

Off

On

efficiency), Hot Water, Heat Pump

 

 

 

Gas or Oil Warm Air (factory setting)

6

Off

Off

 

 

 

 

Electric Warm Air

9

On

Off

 

 

 

 

In Floor Radiant Heat

Check with manufacturer

 

for recommended cycle

 

rate.

 

 

5

68-0279

Page 5
Image 5
Honeywell T8775A specifications Customize Thermostat, DIP Switch, Setting Fuel Switch T8775C only, Set Heat Cycle Rate