T8775A,C THE DIGITAL ROUND™ 
| Rc | B | |
| G | ||
| 2 | ||
| Y | ||
| R | ||
| W | ||
| 
 | 
| COMPRESSOR | 
| CONTACTOR | 
| 
 | HEATING | FAN | 
| 1 | RELAY OR | RELAY | 
| 
 | VALVE COIL | 
 | 
| 1 | 
| FUEL SWITCH | M19497 | 
Fig. 12. Fuel switch.
1POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
2REMOVE FACTORY INSTALLED JUMPER BETWEEN R AND RC.
M19517
Fig. 10. Typical hookup of T8775C in heat-cool  system
with two transformers.
4
| 
 | O | |
| 
 | B | |
| 
 | Rc | |
| 2 | G | |
| Y 3 | ||
| R | ||
| 
 | W | 
DIP Switch
To adjust the heat cycle rate or the Fahrenheit/Celsius temperature display, locate DIP switch 1, 2 and 3 on the back of the thermostat. See Fig. 13.
BACK OF THERMOSTAT
| 
 | COMPRESSOR | 
 | HEAT | 
| 
 | CHANGEOVER | ||
| 
 | CONTACTOR | ||
| 
 | 
 | VALVE | |
| 
 | 
 | 
 | |
| 1 | FAN | 
 | COOL | 
| 
 | 
 | ||
| 
 | RELAY | CHANGEOVER | |
| 
 | VALVE | ||
| 
 | 
 | 
 | |
| 1 | POWER SUPPLY. PROVIDE DISCONNECT MEANS | ||
| 
 | AND OVERLOAD PROTECTION AS REQUIRED. | ||
| 2 | FACTORY INSTALLED JUMPER. | ||
| 3 | USE A JUMPER WIRE (NOT SUPPLIED) TO CONNECT W TO Y. | ||
| 4 | USE EITHER O OR B FOR HEAT PUMP CHANGEOVER. | ||
| 
 | 
 | 
 | M19516 | 
Fig. 11. Typical hookup of T8775C in single-stage  heat
pump system.
CUSTOMIZE THERMOSTAT
Setting Fuel Switch (T8775C only)
The fuel switch is preset at the factory in the F position. See Fig. 12. This is the correct setting for gas or oil systems. If the T8775C is being installed on an electric heat system, or a heat pump, set the switch to the E position. The E position allows the fan to turn on immediately with the heating equipment in a system where the G terminal is connected.
| 
 | 3 | 
| 
 | 2 | 
| ON | 1 | 
M19567
DIP SWITCH
Fig. 13. DIP switch.
Set Heat Cycle Rate
Use DIP switches 1 and 2 to set the heat cycle rate. See Table 1.
Table 1. Heat Cycle Rate.
| 
 | 
 | 
 | 
 | 
| 
 | Cycles | DIP | DIP | 
| Heating System | Per | Switch | Switch | 
| Hour | 1 | 2 | |
| Steam, Gravity | 1 | On | On | 
| 
 | 
 | 
 | 
 | 
| High Efficiency Warm Air (90%+ | 3 | Off | On | 
| efficiency), Hot Water, Heat Pump | 
 | 
 | 
 | 
| Gas or Oil Warm Air (factory setting) | 6 | Off | Off | 
| 
 | 
 | 
 | 
 | 
| Electric Warm Air | 9 | On | Off | 
| 
 | 
 | 
 | 
 | 
| In Floor Radiant Heat | Check with manufacturer | ||
| 
 | for recommended cycle | ||
| 
 | rate. | 
 | 
 | 
| 5 | 