FIRE ALARM SYSTEM (IF INSTALLED)
General Your fire alarm system (if installed) is on 24 hours a day, for continuous protection. In the event of an emergency, the strategically located smoke and heat detectors will automatically send signals to your system, triggering a loud, interrupted pulsed sound* from the Keypad(s). This sound will also be produced by optional exterior sounders. A FIRE message will appear at your Keypad and remain on until you silence the alarm (see below for silencing fire alarms).
*Temporal pulse sounding is produced for Fire alarms, as follows:
3
TYPICAL FIRE EMERGENCY DISPLAYS
FIRE 05
MASTER BEDROOM
ALPHA
05 AC
ALARM
F I R E
Silencing 1. You can silence the alarm at any time by pressing the OFF key (the security code is
Fire Alarms not needed to silence fire alarms). To clear the display, enter your code and press the OFF key again (to clear Memory of Alarm).
2.If the Keypad's fire indication does not clear after the second OFF sequence, smoke detectors may still be responding to smoke or heat producing objects in their vicinity. Investigate, and should this be the case, eliminate the source of heat or smoke.
3.If this does not remedy the problem, there may still be smoke in the detector. Clear it by fanning the detector for about 30 seconds.
4.When the problem has been corrected, clear the display by entering your code and pressing the OFF key.
–2 9 –