6. Position nozzle cover on front lip
of nozzle base. Press cover into
place.
Turn nozzle over and replace
screws.
Agitator brush roll
When to replace
Disconnect cleaner from electri-
cal outlet.
When agitator brushes are worn,
the brush roll should be replaced.
To check condition of brushes,
move the edge of a card across
agitator opening while turning
agitator. To maintain cleaning
effectiveness, replace brushes if
they do not touch card.

How to replace

The brush roll may be replaced
with either a single or double brush
roll.
Single row of brushes
-
Hoover part
No. 48414433.
Double row of brushes
-
Hoover
part No. 48414432.
1. Remove nozzle cover, agitator
and belt following directions in
“How to replace belt”.
2. Turn end plates of agitator in
opposite directions until one end
plate comes off.
15