INSTALLATION
Tumble dryers are supplied to operate at a
voltage of 220-240V, 50 Hz single phase. Check
that the supply circuit is rated to at least 10A.
Electricity can be extremely dangerous.
This appliance must be earthed.
The socket outlet and the plug on the
appliance must be of the same type.
Do not use mult iple adapte rs and/or
extension leads.
The pl ug sh ould b e acc essi ble fo r
disconnection after the appliance has been
installed.
The wires in the mains lead are coloured in
accordance with the following codes:
Blue NEUTRAL
BrownLIVE
Green and Yellow EARTH
Electrical Requirements
If the mains cord on this appliance is
damaged, it must be replaced by a special cord
which is ONLY obtainable from the spares
service. It must be installed by a competent
person.
You may be charged for a service call if a
problem with your machine is caused by
incorrect installation.
Once the machine is in
place the feet should
be adjusted to ensure
that the machine is
level.
Adjusting the Feet
Adequate ventilation must be provided in the
room where the tumble dryer is located to
prevent gases from appliances burning other
fuels, including open fires, being drawn into the
room during operation of the tumble dryer.
Exhaust air must not be discharged into a flue
which is used for exhausting fumes from
appliances burning gas or other fuels.
Check regularly that the air flowing through
the dryer is not restricted.
Check the fluff filter after use, and clean, if
necessary.
The inlet and outlets should be kept free from
obstructions. To ensure adequate ventilation
the space between the bottom of the machine
and the floor must not be obstructed. There
should be a gap of at least 12mm between the
machine and any obstructions.
Prevent items from falling or collecting behind
the dryer as these may obstruct the air inlet and
outlet.
NEVER install the dryer up against curtains.
VENTILATION
Do not plug the machine in and switch it
on at the mains until the installation is
completed.For your safety, this dryer must be
correctly installed. If there is any doubt about
installation, call Customer Care for advice.
Air Outlets
Air Outlets in the Base
Air Inlent Vents
Do not install the product in a room where
there is a risk of frost occurring. At temperature
around freezing point the product may not be
able to operate properly: there is a risk of
damage if the water is allowed to freeze in the
hydraulic circuit (valves, hoses, pumps).
For a better product performance the ambient
room temperature must be between +2°C and
+35°C.