LOCATOR

LOCATOR

Remove brushes by pulling them from agitator with pliers. Slide new brushes into the channels - small ends first - pushing them in as far as possible. (Fig. 4).

Replace end plate and shaft, lining up locator on end section with slot in agitator. Replace other end section and end plate and tighten. (Fig. 5).

END SECTION WAS

BEARIN

5

Should you accidentally displace the bearing during disassembly, re- assemble as shown.

BOTTOM PLATE BRUSH

Periodically, check the Bottom Plate Brush to see whether or not bristles have become worn. Put the Surface Selector Lever in the “Bare Floor” position. Place a straight edge across the brush opening to check the length of the bristles. The bristles should extend beyond the bottom plate, l/16” or more.