38

The headlight

What to buy

This cleaner uses a 12 volt, wedge base type 912 bulb, Hoover part

No. 27313-101.

39

39Pull old bulb straight out of socket. Push new bulb straight

into socket until locked into place.

Excessive force is not required.

40

40Reposition the lens and secure with the two screws.

How to replace

Disconnect cleaner from electrical outlet.

Using a screwdriver, remove

38the two screws as shown and lift off lens.

The belt

41

42

 

The belt on your HOOVER cleaner causes the agitator to rotate and is important for the effective operation of the cleaner. The belt is located under the bottom plate of the cleaner and should be checked from time to time to be sure it is in good condition.

When to replace

To check belt, remove bottom plate and hood as shown in “How to replace belt.” Replace belt if it is stretched, cut or broken.

What to buy

To assure effective operation, use only genuine HOOVER belts with your cleaner. When purchasing a new belt, ask for Hoover part

No. 38528-033.

A

How to replace

Disconnect cleaner from electrical outlet.

Place handle in low position and turn cleaner over so bottom side is up.

Remove the 4 screws as shown

41with a Phillips head screw driver. Lift off bottom plate (A).

42Remove agitator and used belt. Discard used belt.

Continued

9

Page 9
Image 9
Hoover Wind Tunnel warranty Headlight, Belt, How to replace, Excessive force is not required