2. Portion Dispense

Agitating motor energizes for .6 seconds for every 12 seconds of accumulative dispense time. A variable resistor which controls the amount of ice dispensed is located on

the control board. The figures on the label indicate dispensing time (sec.). See "II. D.3.a) Portion Control." When shipped, the portion control is set at the minimum dispensing time (0.6 sec.).

DCM-750BAH(-OS), DCM-750BWH(-OS) . . . . . . . . . . . . Approximately 0.72 oz. Amount of ice dispensed per second.

DCM-750BAH(-OS), DCM-750BWH(-OS) . . . . . . . . . . . . Approximately 1.2 oz.

DCM-750BAH,

DCM-750BWH

DCM-750BAH-OS,

DCM-750BWH-OS

WIRE COLOR CODE

BK

BLACK

BR

BROWN

BU

BLUE

DBU

DARK BLUE

GY

GRAY

LBU

LIGHT BLUE

O

ORANGE

 

W/BK

WHITE/BLACK

P

PINK

 

W/BR

WHITE/BROWN

R

RED

 

W/BU

WHITE/BLUE

V

VIOLET

 

W/O

WHITE/ORANGE

W

WHITE

 

W/R

WHITE/RED

YYELLOW

33