33
2. Portion Dispense
Agitating motor energizes for .6 seconds for every  seconds of accumulative dispense
time. A variable resistor which controls the amount of ice dispensed is located on
the control board. The gures on the label indicate dispensing time (sec.). See "II.
D.3.a) Portion Control." When shipped, the portion control is set at the minimum
dispensing time (0.6 sec.).
DCM-750BAH(-OS), DCM-750BWH(-OS) . . . . . . . . . . . . Approximately 0.7 oz.
Amount of ice dispensed per second.
DCM-750BAH(-OS), DCM-750BWH(-OS) . . . . . . . . . . . . Approximately . oz.
BK BLACK O ORANGE W/BK WHITE/BLACK
BR BROWN P PINK W/BRWHITE/BROWN
BU BLUE R RED W/BU WHITE/BLUE
DBU DARK BLUE V VIOLET W/O WHITE/ORANGE
GY GRAY W WHITE W/R WHITE/RED
LBU LIGHT BLUE Y YELLOW
WIRE COLOR CODE
DCM-750BAH-OS,
DCM-750BWH-OS
DCM-750BAH,
DCM-750BWH