I. Specifications
A. Icemaker
1. DCM-750BAH
AC SUPPLY VOLTAGE | 115/60/1 |
|
|
|
|
COMPRESSOR | 120 V | 13.2 RLA |
| 60 LRA | |
GEAR MOTOR | 120 V | 3 FLA |
| 1/4 HP | |
FAN MOTOR | 120 V | 0.85 FLA |
| 1/15 HP | |
AGITATING MOTOR | 120 V | 1.8 FLA (Total) | 110 W | ||
DISPENSING MOTOR | 120 V | 0.9 FLA |
| 55 W | |
OTHER | 120 V | 0.6 A |
|
|
|
MAXIMUM FUSE SIZE | 20 A |
|
|
|
|
MAX. HACR BREAKER (USA ONLY) | 20 A |
|
|
|
|
MAX. CIRC. BREAKER (CANADA ONLY) | 20 A |
|
|
|
|
MINIMUM CIRCUIT AMPACITY | 20 A |
|
|
|
|
APPROXIMATE ICE PRODUCTION | Ambient | WATER TEMP. (°F) |
| ||
PER 24 HR. | Temp.(°F) | 50 | 70 | 90 |
|
lbs./day ( kg/day ) | 70 | * 803 (364) | 770 (349) | 726 (329) |
|
Reference without *marks | 80 | 684 (310) | 645 (293) | 608 (276) |
|
| 90 | 573 (260) | * 567 (257) | 509 (231) |
|
SHAPE OF ICE | 100 | 480 (218) | 452 (205) | * 423 (192) |
|
Cubelet | (Compressed Flake Ice) |
|
| ||
ICE QUALITY | Approx. 90%, Ice (90/70°F, Conductivity 200 µs/cm) | ||||
APPROXIMATE STORAGE CAPACITY | 95 lbs. |
|
|
|
|
ELECTRIC & WATER CONSUMPTION | 90/70°F |
| 70/50°F |
|
|
ELECTRIC W (kWH/100 lbs.) | 1481 (6.3) |
| 1449 (4.3) |
|
|
POTABLE WATER | 68 (12) |
| 96 (12) |
|
|
gal./24HR (gal./100 lbs.) |
|
|
|
|
|
EXTERIOR DIMENSIONS (WxDxH) | |||||
EXTERIOR FINISH | Stainless Steel; Galvanized Steel (Rear) | ||||
WEIGHT | Net 375 lbs. ( 170 kg ), Shipping 405 lbs. ( 184 kg ) | ||||
CONNECTIONS - ELECTRIC | Permanent Connection |
|
|
| |
- WATER SUPPLY | Inlet 1/2" FPT |
|
|
| |
- DRAIN | Drain Pan 3/4" FPT |
|
|
| |
| Bin Drain 3/4" FPT |
|
|
| |
ICE MAKING SYSTEM | Auger type |
|
|
|
|
HARVESTING SYSTEM | Direct Driven Auger ( 1/4 HP Gear Motor ) | ||||
ICE MAKING WATER CONTROL | Float Switch |
|
|
| |
COOLING WATER CONTROL | N/A |
|
|
|
|
BIN CONTROL SYSTEM | Mechanical Bin Control ( Proximity Sw. ) | ||||
COMPRESSOR | Hermetic, | Model | |||
CONDENSER |
|
| |||
EVAPORATOR | Copper Tube on Cylinder |
|
|
| |
REFRIGERANT CONTROL | Thermostatic Expansion Valve |
|
| ||
REFRIGERANT CHARGE | 1 lb. 7.1 oz. (660 g) |
|
| ||
DESIGN PRESSURE | High 460 PSIG, Low 290 PSIG |
|
| ||
P.C. BOARD CIRCUIT PROTECTION | High Voltage |
|
| ||
COMPRESSOR PROTECTION |
|
| |||
GEAR MOTOR PROTECTION | Manual reset Circuit Breaker |
|
| ||
REFRIGERANT CIRCUIT PROTECTION | |||||
LOW WATER PROTECTION | Float Switch and Timer |
|
|
| |
ACCESSORIES - SUPPLIED | Spare Fuse |
|
|
|
|
- REQUIRED | Legs |
|
|
|
|
OPERATING CONDITIONS | VOLTAGE RANGE |
| 104 - 127 V | ||
| AMBIENT TEMP. |
| 45 - 100° F | ||
| WATER SUPPLY TEMP. |
| 45 - 90° F | ||
| WATER SUPPLY PRESSURE | 10 - 113 PSIG |
Note: We reserve the right to make changes in specifications and design without prior notice.