2. Water-Cooled Condenser

2. Water-Cooled Condenser

a) Connection to an Open Drain System

Condenser water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended for the condenser water supply line.

A condenser water supply line shut-off valve and drain valve should be installed.

Condenser drain outlet is 3/8" FPT. A minimum of 3/8" OD hard pipe is recommended for the condenser drain line.

In some areas, a back flow preventer may be required in the condenser water supply line.

Storage Bin

Drain Outlet

3/4" FPT

Drip Tray

Drain Outlet

3/4" FPT

Icemaker

Stand

Vent

Tube

Icemaker Water

 

Supply Inlet

 

1/2" FPT

Icemaker Water Supply

 

Condenser

Line Shut-Off Valve

 

Drain Outlet

 

3/8" FPT

 

 

Icemaker Water Supply

 

Line Drain Valve

Vent

 

Tube

Condenser Water Supply

 

Line Shut-Off Valve

 

Condenser Water

 

Supply Line Drain Valve

Condenser Water Supply Inlet 1/2" FPT

Separate piping to approved drain. Leave a two-inch (5 cm) vertical air gap between the end of each pipe and the drain.

Two-inch (5 cm) air gap

Fig. 5

Floor Drain

DCM-750BWH(-OS)

Connection to an Open Drain System

20

Page 20
Image 20
Hoshizaki DCM-750BWH(-OS) DCM-750BWH-OS Connection to an Open Drain System, a Connection to an Open Drain System, Fig