33
e) Bin Control Selector (S1 dip switch 7)
This unit is factory set for infrared sensor bin control operation. No adjustment is
required. When used on a standard ice storage bin, the mechanical bin control may be
used instead of the infrared sensor by moving S1 dip switch 7 to the off position. In the
factory default position (S1 dip switch 7 in the on position), the gear motor delay after the
upper oat switch closes is 30 seconds. When the mechanical bin control is used (S1 dip
switch 7 in the off position), the gear motor delay after the upper oat switch closes is
5 seconds. WARNING! Do not place S1 dip switch 7 in the off position on dispenser
unit applications.
S1 Dip Switch
Setting Bin Control Application Gear Motor Delay
No. 7
OFF Mechanical Bin Control (Standard Ice Storage Bins Only) 5 seconds
ON Infrared Sensor with
Mechanical Bin Control Backup 30 seconds
f) Mechanical Bin Control Shutdown Delay (S1 dip switch 8)
Factory set for normal operation. No adjustment is required. The shutdown delay is the
time between the mechanical bin control proximity switch opening and the control board
shutting off the icemaker.
S1 Dip Switch
Setting Bin Control #1
Shutdown Delay
No. 8
OFF 0.5 Seconds
ON 6.7 Seconds
g) Factory Use (S1 Dip Switch 9 & 10)
Factory set for optimum performance. Do not adjust.