55
APPROXIMATE Ambient Water Temp. (°F)
ICE PRODUCTION Temp. (°F)
PER 24 HR. 70 *930 *(423) 895 (406) 860 (390)
80 825 (375) 790 (360) 760 (345)
90 730 (332) *720 *(326) 670 (306)
lbs./day (kg/day) 100 645 (294) 620 (282) *580 *(263)
APPROXIMATE ELECTRIC 70 *1401 -- 1408 -- 1415 --
CONSUMPTION 80 1422 -- 1428 -- 1435 --
90 1442 -- *1449 -- 1444 --
watts 100 1440 -- 1435 -- *1430 --
APPROXIMATE WATER 70 *112 *(423) 108 (406) 103 (390)
CONSUMPTION PER 24 HR. 80 99 (375) 95 (360) 91 (345)
90 88 (332) *86 *(326) 81 (306)
gal./day (l/day) 100 78 (294) 75 (282) *70 *(263)
EVAPORATOR OUTLET TEMP. 70 *5 *(-15) 5 (-15) 5 (-15)
80 5 (-15) 9 (-13) 9(-13)
90 9 (-13) *9 *(-13) 12 (-11)
°F (°C) 100 12 (-11) 12 (-11) *12 *(-11)
HEAD PRESSURE 70 *205 *(14.4) 205 (14.4) 205 (14.4)
80 234 (16.5) 234 (16.5) 234 (16.5)
90 264 (18.6) *264 *(18.6) 264 (18.6)
PSIG (kg/cm²G) 100 301 (21.1) 301 (21.1) 301 *(21.1)
SUCTION PRESSURE 70 *33 *(2.3) 33 (2.3) 33 (2.3)
80 35 (2.4) 35 (2.4) 35 (2.4)
90 36 (2.6) *36 *(2.6) 36 (2.6)
PSIG ( kg/cm²G ) 100 39 (2.7) 39 (2.7) *39 *(2.7)

CONDENSER VOLUME 74.5 cu in

HEAT OF REJECTION FROM CONDENSER 8900 BTU/h (AT 90°F /WT 70°F)

HEAT OF REJECTION FROM COMPRESSOR1400 BTU/h (AT 90°F /WT 70°F)

50 70 90
Note: We reserve the right to make changes in specications and design without prior
notice.
6. FD-1001MRH-C (remote air-cooled)