99
4) Remove the proximity switch from the chute assembly, then remove the chute assembly
from the icemaker.
5) Remove the packing at the bottom of the ice chute. Remove the 3 ties and the chute
insulation.
6) Remove the bafes.
7) Remove the plate and the packing from the top of the ice chute, then remove the
backup bin control assembly by sliding it slightly towards the chute opening and lifting it
off.
8) Disassemble the backup bin control assembly by removing the snap pins, shaft, and
actuator.
9) Soak the spout, O-ring, packings, chute, bafes, plate, and backup bin control assembly
in the sanitizing solution for 10 minutes then wipe them down.
10) Rinse the parts thoroughly with clean water.
CAUTION
If the solution is left on these parts, they will rust.
11) Replace all parts in their correct positions.
IMPORTANT
When installing the bafes, make sure that the bent surface (the one without
the studs) faces the actuator so that the bent surface can guide the ice to the
center of the actuator.
1) Move the control switch to the "ICE" position, then move the power switch to the "ON"
position. Replace the panels in their correct positions, then turn on the power supply.
Make ice using the solution until the icemaker stops making ice.
13) Turn off the power supply, then remove the front panel. Move the control switch to the
"DRAIN" position, then replace the front panel in its correct position.
14) Turn on the power supply and allow the solution to drain for 5 minutes.
15) Turn off the power supply.
5. Sanitizing Procedure - Final
1) Mix a new batch of the sanitizing solution.
) Make sure the power supply is off and the water supply line shut-off valve is closed.
Remove the front and top panels, then move the power switch to the "OFF" position.
3) Remove the strap connecting the spout to the chute assembly, then remove the spout.
4) Pour the sanitizing solution over the extruding head until the evaporator assembly and
the reservoir are full and the solution starts to overow into the drain pan.
5) Replace the spout and strap in their correct positions.
6) Allow the icemaker to sit for about 10 minutes before operation.
7) Move the control switch to the "ICE" position, then move the power switch to the "ON"