Hoshizaki IM-500SAA manual 2Turn off the power supply

Models: IM-500SAA

1 24
Download 24 pages 14.37 Kb
Page 12
Image 12
2)Turn off the power supply.

12

1)Dilute approximately 7.2 fl. oz. (214 ml) of recommended cleaner Hoshizaki “Scale Away” with 0.8 gal. (3.0 lit.) of water.

2)Turn off the power supply.

3)Remove all ice from the storage bin.

4)Remove the front panel.

5)Remove the screw, and then move the water tank drain pipe to the drain position. See Fig. 5. Use the screw to secure the water tank drain pipe in the drain position.

6)Make sure the control switch is in the “ICE” position, and then replace the front panel.

7)Close the icemaker water supply line shutoff valve.

8)Turn on the power supply for 3 minutes. The water tank drains and cubes are removed from the evaporator.

9)Turn off the power supply.

10)Remove the front panel and top panel.

11)Move the control switch to the “WASH“ position.

12)Slowly pour the cleaning solution over the top of the evaporator and into the water tank. Do not splash or spill the solution onto other parts.

13)Replace the front panel and top panel in their correct positions.

Page 12
Image 12
Hoshizaki IM-500SAA manual 2Turn off the power supply