Hoshizaki IM-500SAA manual 5Remove the front panel and top panel

Models: IM-500SAA

1 24
Download 24 pages 14.37 Kb
Page 14
Image 14
5)Remove the front panel and top panel.

14

5)Remove the front panel and top panel.

6)Move the control switch to the “WASH“ position.

7)Slowly pour the sanitizing solution over the top of the evaporator and into the water tank. Do not splash or spill the solution onto other parts.

8)Replace the front panel and top panel in their correct positions.

9)Turn on the power supply to start the sanitizing process.

10)Turn off the power supply after 15 minutes.

11)Open the icemaker water supply line shut-off valve.

12)Remove the front panel.

13)Move the control switch to the “ICE“ position.

14)Replace the front panel.

15)Turn on the power supply for 3 minutes. The water tank drains.

16)Turn off the power supply.

17)Repeat steps 15 and 16 three more times to rinse thoroughly.

18)Repeat steps 1 through 17 one more time.

19)Remove the front panel.

20)Remove the screw, then move the water tank drain pipe to the normal position. See Fig. 5. Use the screw to secure the water tank drain pipe in the normal position.