SANITIZING:

13

14)Turn on the power supply to start the washing process.

15)Turn off the power supply after 30 minutes.

16)Open the icemaker water supply line shut-off valve. See Fig. 4.

17)Remove the front panel.

18)Move the control switch to the "ICE" position.

19)Replace the front panel.

20)Turn on the power supply for 3 minutes. The water tank drains.

21)Turn off the power supply.

22)Repeat steps 20 and 21 three more times to rinse thoroughly.

SANITIZING:

1)Dilute a 5.25% sodium hypochlorite solution (chlorine bleach) with water (add approximately 0.4 fl . oz. (12 ml) to 0.8 gal. (3.0 lit.) of water).

2)Close the icemaker water supply line shut-off valve.

3)Turn on the power supply for 3 minutes. The water tank drains.

4)Turn off the power supply.