24)Turn off the power supply after 5 minutes.

25)Remove the Front Panel and the Insulation Panel.

26)Remove the Cap located on the front bottom part of the Ice Dropping Hole. Drain the Water Tank. Replace the Cap and the Insulation Panel in their correct position.

Note: Do not replace the Insulation Panel when you proceed to “[b] SANITIZING PROCEDURE.”

27) Repeat the above steps 15) through 26) three more times to rinse thoroughly.

Note: If you do not sanitize the icemaker, go to the step 9) in “[b] SANITIZING PROCEDURE.”

[b] SANITIZING PROCEDURE - Following Cleaning Procedure

1)Dilute IMS-II Sanitizer or a 5.25% Sodium Hypochlorite solution with water (Add 2.5 fl. oz. of sanitizer to 5 gal. of water).

Note: IMS-II Sanitizer, Part #SA0004, is available through your Hoshizaki Dealer.

2)Pour the sanitizing solution into the Water Tank.

3)Replace the Insulation Panel and the Front Panel in their correct position.

Note: Make sure that the Control Switch is in the “WASH” position and the Cleaning Valve is open.

4)Turn on the power supply, and start the sanitizing process.

5)Turn off the power supply after 15 minutes.

6)Remove the Front Panel and the Insulation Panel.

7)Remove the Cap located on the front bottom part of the Ice Dropping Hole. Drain the Water Tank. Replace the Cap and the Insulation Panel in their correct position.

8)Repeat the above steps 15) through 26) in “[a] CLEANING PROCEDURE” two times to rinse thoroughly.

9)Close the Cleaning Valve.

10)Move the Control Switch to the “ICE” position.

11)Replace the Front Panel in its correct position.