Hoshizaki instruction manual KM-650MAH and KM-650MRH, Icemaker

Models: KM-650MAH

1 32
Download 32 pages 59.37 Kb
Page 21
Image 21
1. Icemaker

1. Icemaker

Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended for the icemaker water supply line.

An icemaker water supply line shut-off valve and drain valve should be installed.

Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" OD hard pipe is recommended for the icemaker drain line. Condensation drain outlet is 3/8" OD stainless tube. The condensation drain line can be connected to the icemaker drain line or can be run separately.

Icemaker

Water Supply

Inlet

1/2" FPT

Condensation

Drain Outlet

3/8" OD Stainless

Tube

Icemaker

Drain Outlet

3/4" FPT

Icemaker

Bin

Icemaker Water Supply Line

Shut-Off Valve

Icemaker Water Supply Line

Drain Valve

Bin Drain Outlet 3/4" FPT

Separate piping to approved drain. Leave a two-inch (5 cm) vertical air gap between the end of each pipe and the drain.

Two-inch (5 cm) air gap

Floor Drain

Fig. 11

KM-650MAH and KM-650MRH

21

Page 21
Image 21
Hoshizaki instruction manual KM-650MAH and KM-650MRH, Icemaker