I. Startup
WARNING
1.All parts are
2.If the icemaker is turned off, wait for at least 3 minutes before restarting the icemaker to prevent damage to the compressor.
3.To prevent damage to the water pump seal, do not operate the icemaker with the control switch in the "WASH" position when the water tank is empty.
4.At startup, confirm that all internal and external connections are free of leaks.
5.On remote
1)Open the water supply line
2)Remove the front panel.
3)Move the control switch on the control box to the "ICE" position.
4)Replace the front panel in its correct position.
5)Turn on the power supply, and allow the icemaker to operate for a total of 10 minutes.
6)Turn off the power supply, then remove the front panel.
7)Remove the base cover, then disconnect one end of the pump tubing to drain the water tank. See Fig. 14.
8)After the water tank has drained, reconnect the pump tubing.
9)Clean the storage bin liner using a neutral cleaner. Rinse thoroughly after cleaning.
10)Replace the base cover and the front panel in their correct positions.
11)Turn on the power supply to start the automatic icemaking process.
12)To confirm bin control operation, press and hold the bin control's actuator paddle during the first 5 minutes of the freeze cycle. The icemaker should shut down in approximately 15 seconds.
Disconnect This
End of Pump
Tubing to Drain
Water Tank
Base Cover
Fig. 14
25