1. Icemaker

Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended for the icemaker water supply line.

An icemaker water supply line shut-off valve and drain valve should be installed.

Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" OD hard pipe is recommended for the icemaker drain line.

Icemaker

Icemaker

Water Supply

Inlet

Icemaker Water Supply Line

1/2" FPT

Shut-Off Valve

 

Icemaker Water Supply Line

 

Drain Valve

Icemaker

Drain Outlet

3/4" FPT

Bin Drain Outlet 3/4" FPT

Bin

Separate piping to approved drain.

Leave a two-inch (5 cm) vertical air

 

 

gap between the end of each pipe

 

and the drain.

 

Two-inch

 

(5 cm) air

 

gap

Floor Drain

Fig. 7

KMD-450MAH

14

Page 14