Hoshizaki KMD-450MWH, KMD-450MAH instruction manual Close the drain valves

Models: KMD-450MAH KMD-450MWH

1 25
Download 25 pages 45.26 Kb
Page 24
Image 24

3)Open the condenser water supply line drain valve. If connected to a closed loop system, also open the condenser return line drain valve.

4)Attach a compressed air or carbon dioxide supply to the condenser water supply line drain valve.

5)Open the water regulating valve by using a screwdriver to pry up on the spring retainer underneath the spring. While holding the valve open, blow out the condenser using the compressed air or carbon dioxide supply until water stops coming out.

6)Close the drain valve(s).

7)Replace the right side panel and front panel in their correct positions.