2. Water-Cooled Condenser (if applicable)
a) Connection to an Open Drain System
•Condenser water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended for the condenser water supply line.
•A condenser water supply line
•Condenser drain outlet is 1/2" FPT. A minimum of 3/8" OD hard pipe is recommended for the condenser drain line.
•In some areas, a back flow preventer may be required in the cooling water circuit.
Icemaker Water | Icemaker |
| |
Supply Inlet |
|
1/2" FPT |
|
Condenser Water
Supply Inlet
1/2" FPT
Condenser Bin
Drain Outlet
1/2" FPT
Icemaker
Drain Outlet
3/4" FPT
Bin Drain Outlet 3/4" FPT
Icemaker Water Supply
Line
Condenser Water Supply Line
Icemaker Water Supply Line
Drain Valve
Condenser Water Supply Line
Drain Valve
Separate piping to approved drain. Leave a
Floor Drain
Fig. 8 |
|
| Connection to an Open Drain System |
15