Separator (inside)
*
Door
Air Inlet*
(Air Filter)
Air Filter* |
|
Louver | How to remove Louver |
|
Magnet Catch
Fig. 1
C. Location
WARNING
This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within +45°F to +100°F (+7°C to +38°C); Normal operating water temperature should be within +45°F to +90°F (+7°C to +32° C). Operation of the icemaker, for extended periods, outside of these normal temperature ranges may affect production capacity.
For best operating results:
*The icemaker should not be located next to ovens, grills or other high heat producing equipment.
*Level the icemaker from side to side and front to rear by adjusting the legs. The location should provide a firm and level foundation for the equipment.
*Avoid a site where dripping is not allowed.
*This icemaker will not work at subfreezing temperatures. To prevent damage to the water supply line, drain the icemaker when air temperature is below zero.
*Allow at least 2” (5 cm) clearance at the right side for proper air circulation and at least 0.6” (15 mm) clearance at top for ease of maintenance and/or service.