2)Soak the removed parts from step 17 above in a clean container containing the sanitizing solution. After allowing the parts to soak for 10 minutes, wash them with the solution. Also wash the bin liner, Bracket (L) (R) with the solution.
3)Discard the sanitizing solution and rinse the parts thoroughly with water.
4)Replace the removed parts in their correct positions in the reverse order of which they were removed.
5)Same as step 1.
6)Pour the sanitizing solution into the Water Tank, and allow the sanitizer to sit for 10 minutes.
7)Move the Control Switch to the “SERVICE” position and the Service Switch to the “WASH” position.
8)After 15 minutes, move the Control Switch to the “OFF” position.
9)Move the Control Switch to the “SERVICE” position and the Service Switch to the “DRAIN” position.
10)After 2 minutes, move the Control Switch to the “OFF” position.
11)Repeat steps 5 through 10 one time. Repeat steps 9 through 12 in the Cleaning Procedure three times to rinse thoroughly.
12)Flush the Storage Bin with water.
13)Move the Control Switch to the “ICE” position, and start the automatic icemaking process.
14)Close the Door. Replace the Louver in its correct position.
B. Maintenance
1. Exterior Panels
To prevent corrosion, wipe the exterior occasionally with a clean and soft cloth. Use a damp cloth containing a neutral cleaner to wipe off all oil or dirt build up.
2. Storage Bin and Scoop
* Wash your hands before removing ice. Use the plastic scoop provided (Accessory).