1 16
Download 16 pages 4.57 Kb
Page 4
Image 4
Fixing
UNDERSIDE OF HOB

 

Fixing

GB

The appliance must be installed on a perfectly level

 

 

supporting surface.

 

 

Any deformities caused by improper fixing could affect

 

the features and operation of the hob.

 

The thickness of the supporting surface should be taken

 

into account when choosing the length of the screws for

 

the fixing hooks:

 

30 mm thick: 17.5 mm screws

 

40 mm thick: 7.5 mm screws

Fix the hob as follows:

1.Use short flat-bottomed screws to fix the 4 alignment springs in the holes provided at the central point of each side of the hob.

2.Place the hob in the cavity, make sure it is in a central position and push down on the whole perimeter until the hob is stuck to the supporting surface.

3.For hobs with raised sides: After inserting the hob into its cavity, insert the 4 fixing hooks (each has its own pin) into the lower edges of the hob, using the long pointed screws to fix them in place, until the glass is stuck to the supporting surface.

!The screws for the alignment springs must remain accessible.

!In order to adhere to safety standards, the appliance must not come into contact with electrical parts once it has been installed.

!All parts which ensure the safe operation of the appliance must not be removable without the aid of a tool.

Electrical connection

!The electrical connection for the hob and for any built- in oven must be carried out separately, both for safety purposes and to make extracting the oven easier.

Terminal board

On the lower part of the appliance there is a connection box for the different

types of electricity supply (the

picture is only an indication and

is not an exact representation of the purchased model).

Single-phase connection

The hob is equipped with a pre-connected electricity supply cable, which is designed for single-phase

connection. Connect the wires in accordance with the instructions given in the following table and diagrams:

Voltage and

 

Electrical cable

Wire connection

mains frequency

 

 

 

 

 

 

 

 

 

 

230-240V 1+N ~

 

 

: yellow/green

 

 

N: the two blue wires together

220-240V 1+N ~

 

 

 

 

L: brown and black together

50/60 Hz

 

 

 

 

 

 

 

Other types of connection

If the mains supply corresponds with one of the following:

Voltage and mains frequency

400V - 2+N ~ 50/60 Hz

220-240V 3 ~ 50/60 Hz

230-240V 3 ~ 50/60 Hz

400V - 2+2N ~ 50/60 Hz

Separate the wires and connect them in accordance with the instructions given in the following table and diagrams:

Voltage and

Electrical cable

Wire connection

mains frequency

 

 

400V - 2+N ~

 

: yellow/green;

 

 

50/60 Hz

 

N: the two blue wires

 

 

230-240V 3 ~

 

together

220-240V 3 ~

 

L1: black

50/60 Hz

 

L2: brown

 

 

 

 

 

: yellow/green;

400V - 2+2N ~

 

N1: blue

50/60 Hz

 

N2: blue

 

 

L1: black

 

 

L2: brown

 

 

 

If the mains supply corresponds with one of the following:

Voltage and mains frequency

400V 3 - N ~ 50/60 Hz proceed as follows:

!The cable provided is not suitable for the following types of installation.

1.Use a suitable supply cable, H05RR-F or higher, with the right dimensions (cable cross section: 25 mm).

2.To open the terminal board, use a screwdriver as

a lever under the side tabs of the cover (see Terminal board picture).

3.Loosen the cable clamp screw and the terminal board screws in accordance with the type of connection required and position the connection supports as shown in the following table and diagrams.

4.Position the wires in accordance with the information given in the following table and diagrams and connect the appliance by tightening all the screws for the springs as much as possible.

PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24

4

Page 4
Image 4
Hotpoint KSC 640 X S Electrical connection, Fixing, Terminal board, Single-phase connection, Other types of connection