Installation
GB LOCATION
The cooker may be located in a kitchen, kitchen/diner or a
When adjusted for use on Butane (G30) or Propane (G31), the cooker must not be installed in a room or internal space below ground level, e.g. in a basement.
PROVISION FOR VENTILATION
The room containing the cooker should have an air supply in accordance with BS 5440: Part 2.
The room must have an opening window or equivalent; some rooms may also require a permanent vent. If the room has a volume between 5 and 10m3, it will require an air vent of 50cm2 effective area unless it has a door which opens directly to outside. If the room has a volume of less than 5m3, it will require an air vent of 100cm2 effective area. If there are other fuel burning appliances in the same room, BS 5440: Part 2 should be consulted to determine air vent requirements.
TECHNICAL DATA
Gas connection | Rp ½ (½” BSP female) |
Pressure test point | Front left hotplate |
injector |
|
Gas rate adjustment | None |
Aeration adjustment | None |
Electrical connection | Flexible cord fitted with a |
| 3 pin 13 amp plug |
| 230/240V a.c. 50Hz. |
| 13A fuse. |
a)The cooker may be located in a kitchen, a kitchen/ diner or bed sitting room, but not in a bathroom or shower room.
b)The hoods must be installed according to the requirements in the hood handbook.
c)The wall in contact with the back of the cooker must be of flameproof material.
d)The cooker is fitted with a safety chain that must be attached to a hook, secured to the wall behind the appliance.
!Some models can have their
gas connection inverted. It is important to make sure the safety chain is always situated on the
side which corresponds to the hose holder (Fig. B).
SPACE FOR FIXING
The cooker can be close fitted below hotplate level. This requires a minimum distance of 600mm between cupboard units of hotplate height.
When installing next to a tall cupboard, partition or wall, for a minimum distance of 400mm above hotplate level, allow a side clearance of at least 65mm. The diagram below illustrates the minimum clearance between the cooker and adjacent walls, cupboards etc.
The wall behind the cooker, 50mm below and 450mm above, and the width of the cooker, must be a non- combustible material such as ceramic wall tiles.
If the cooker is to be fitted close to a corner on the left hand side, ensure that there is a clearance of at least 50mm to allow the main oven door to open fully for when removing oven shelves.
mmMin | Min |
|
750mm | 65 mm Min | |
|
| |
400 |
|
|
| 600 mm Min |
|
COOKER HOODS
If a cooker hood is to be installed, refer to the cooker hood manufacturers’ instructions regarding fixing height.
UNPACKING THE COOKER
Unpack the components from inside the grill and oven. Check that the following parts are present:
Grill pan and grid | Top oven/grill shelf heat |
shield |
|
Pan supports | Main oven shelves (2) |
Enamelled burner caps (4) | Top oven/grill shelf (1) |
Aluminium burner bodies(4) Literature
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24