Installation
WARNING – THIS APPLIANCE MUST BE EARTHED.
Your cooker should have been checked to ensure that the voltage corresponds with your supply voltage, this is stated on the rating plate, which is situated on the front of the plinth. The cooker must be connected by a com- petent person eg. (NICEIC registered contractor) to suitable
The power supply cable should conform to B.S.6004 with a conductor size of 2.5mm2 minimum.
The control unit should be easily accessible in the event of an emergency, but must be within 2 metres of and not directly above an appliance.
This appliance conforms to EN 55014 regarding suppression of radio and television interference.
Access to the mains terminals is gained by removing the rear access cover.
The mains cable must pass through the cable clamp adjacent to the terminal block. Sufficient cable should be used to allow the cooker to be pulled out for servicing.
Ensure that the mains cable is routed away from any brackets affixed to the rear panel and is not trapped to the rear wall when pushing the cooker into position between cabinets.
26