Electrical connection

Electrical connection

THE APPLIANCE MUST BE EARTHED

Install a standardised plug corresponding to the load indicated on the appliance data plate (see Technical data table). The appliance must be directly connected to the mains using an omnipolar switch with a minimum contact opening of 3

mminstalled between the appliance and the mains. The switch must be suitable for the charge indicated and must comply with current electrical regulations (the earthing wire must not be interrupted by the switch). The supply cable must be positioned so that it does not come into contact with temperatures higher than 50°C at any point.

Before connecting the appliance to the power supply, make sure that:

• The appliance is earthed and the plug is compliant with the law.

• The socket can withstand the maximum power of the appliance, which is indicated by the data plate.

• The voltage is in the range between the values indicated on the data plate.

• The socket is compatible with the plug of the appliance.

If the socket is incompatible with the plug, ask an authorised technician to replace it. Do not use extension cords or multiple sockets.

!Once the appliance has been installed, the power supply cable and the electrical socket must be easily accessible.

!The cable must not be bent or compressed.

!The cable must be checked regularly and replaced by authorised technicians only.

!The manufacturer declines any liability should these safety measures not be observed.

IF THE FITTED PLUG IS REMOVED

The flexible mains lead must be correctly connected as below to a three pin plug of not less than 13 amp capacity. If a B.S. 1363 fused plug is used, it must be fitted with a fuse which is approved to B.S. 1362.

Important: the wires in the mains lead are coloured in accordance with the following code:

Connect the Green & Yellow wire to terminal marked “E

or THE APPLIANCE MUST BE EARTHED or coloured Green or Green & Yellow.GB Connect the Brown wire to the terminal marked “L” or coloured Red.

Connect the Blue wire to the terminal marked “N” or coloured Black.

FAILURE TO OBSERVE THE ACCIDENT-PREVENTION REGULATIONS RELIEVES THE MANUFACTURER OF ALL LIABILITY.

IF A MOULDED PLUG IS FITTED

In the event of replacing a fuse in the plug supplied an ASTA approved fuse to BS1362 must be fitted.

NOTE: The fuse cover must be refitted when changing the fuse. In the event of losing the fuse cover the plug must not be used until a replacement fuse cover has been obtained and fitted. A new fuse cover can be obtained from your local Electricity Board.

The colour of the correct replacement fuse cover is that of the coloured marks or inserts in the base of the plug.

Make sure that the cable does not become trapped when pushing the cooker into position.

Replacing the cable

Use a rubber cable of the type H05VV-F with a cross section of 3 x 1.5 mm². The yellow-green earth wire must be 2 ÷ 3 cm longer than the other wires.

Green & Yellow

- Earth

Blue

- Neutral

Brown

- Live

The power supply cable must be type H05VV-F

Green & Yellow to Earth IF THE FITTED PLUG IS REMOVED

IF A MOULDED PLUG IS FITTED Brown to Live

Blue to

3 Amp

Neutral

Fuse

Cord

Clamp

As the colours of the wires in the mains lead may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:

Technical Characteristics

Grill

Usable Volume: 19 Litres

 

heating mode: Conventional

Main Oven

Usable Volume: 41 Litres
heating mode: Conventional

Voltage and Frequency

220-240V~ 50/60Hz