Burner and Nozzle Specification
GB
V
Fig.E
I |
Fig.F |
Important |
|
On completion of the operation, replace the old rating | 52TGW |
sticker with one indicating the new type of gas used. | |
This sticker is available from our Service Centres. | HAL 51 P |
Note | HAG 51 P |
Should the pressure of the gas used be different (or | |
vary) from the recommended pressure, it is necessary | HAG 51 K |
to fit a suitable pressure regulator onto the inlet pipe in | HAG 51 X |
compliance with current National Regulations relative | |
to “regulators for channelled gas”. | HAG 51 G |
SS
A R
Table 1 |
|
|
|
|
|
|
| Liquid Gas |
|
|
| Natural Gas | ||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Burner | Diameter | Thermal Power | Nozzle |
| Flow* | Nozzle | Flow* | |||||||
|
|
|
| kW (p.c.s.*) | 1/100 | 1/100 |
|
| g/h | 1/100 | l/h | |||
| (mm) | Nominal |
| Reduced | (mm) | (mm) | *** |
|
| ** | (mm) |
| ||
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fast | 100 |
| 94 | 2,60 |
| 0,7 | 41 | 80 | 189 |
|
| 186 | 118 | 286 |
(Large)(R) |
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Semi Fast | 75 |
| 69 | 1,90 |
| 0,4 | 30 | 70 | 138 |
|
| 136 | 104 | 181 |
(Medium)(S) |
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Auxiliary | 51 |
| 46 | 1,00 |
| 0,4 | 30 | 52 | 73 |
|
| 71 | 76 | 95 |
(Small)(A) |
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Oven |
| - | 2,60 |
| 0,6 | 36 | 71 | 189 |
|
| 186 | 115 | 248 | |
Grill |
| - | 2,50 |
| 1,3 | 63 | 80 | 182 |
|
| 179 | 122 | 238 | |
Supply |
|
| Nominal (mbar) |
|
|
| 37 | 20 |
| |||||
|
| Minimum (mbar) |
|
| 20 |
|
| 25 | 17 |
| ||||
Pressures |
|
|
|
|
|
|
| |||||||
|
| Maximum (mbar) |
|
| 35 |
|
| 45 | 25 |
| ||||
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*At 15°C and 1013 mbar- dry gas
** | Propane | P.C.S. = 50,37 MJ/Kg |
***Butane P.C.S. = 49,47 MJ/Kg Natural P.C.S. = 37,78 MJ/m3
8 PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24