Hotpoint HUD 61G S, HUD 61K S Electrical Connection, Operational Checks, Electrical connection

Models: HUD 61P S HAD60 S DSD 60 S S HUD 61G S HUD 61X S HUD 61K S

1 28
Download 28 pages 26.91 Kb
Page 8
Image 8
Electrical Connection

Electrical Connection

Warning - THIS APPLIANCE MUST BE EARTHED

GB The cooker must be connected by a qualified electrician to a suitable double - pole control unit with a minimum rating of 32A and a minimum contact clearance of 3mm, which should be fitted adjacent to (but not above) the cooker, in accordance with IEE regulations.

The power supply cable should conform to BS6004 with a conductor size of 6mm2.

The control unit should be easily accessible in the event of an emergency.

This appliance conforms to EN55014 regarding suppression of radio and television interference.

Access to the cooker terminals is by un-clipping the cover. The mains cable must pass through the cable clamp and the screws must be fully tightened.

Sufficient cable should be used to allow the cooker to be pulled out for servicing. Ensure that the cover is fully closed and secure afterwards.

Take care not to trap the mains cable when pushing the cooker into its final position.

1

Open the terminal

board by inserting a

screwdriver into the

side tabs of the cover.

Use the screwdriver as

a lever by pushing it

down to open the cover

(see diagram).

2

Loosen the cable

clamp screw and

remove it, using a

screwdriver as a lever

(see figure).

3

Remove the wire

contact screws L-N- ,

then fasten the wires

under the screw heads,

respecting the colour

code: Black/Blue (N),

Red/Brown (L) and Bare Wire/Yellow-Green ( )

lOnce the connections have been made, tighten all the terminal screws fully.

Operational Checks

After installation, check for gas soundness. The

l Fasten the supply cable in place with the clamp

and close the cover of the terminal board.

supply pressure can be checked at one of the

 

hotplate burner injectors.

 

Check that the hotplate burners ignite correctly

 

and burn with a steady flame.

 

Check for a steady flame at the low setting.

 

Instruct the user on the operation of the cooker.

 

WARNING – THIS APPLIANCE MUST BE

EARTHED .

Electrical connection

Electric cookers come without a power supply cable. The cooker is designed to operate on an electricity supply which conforms to the electrical data shown on the Rating Plate. The cooker can be connected to the mains only after removing the back panel of the cooker itself with a screwdriver.

N.B.: the following installation procedure must be carried out by a qualified electrician. The electrical installation must comply with the IEE Regulations, Building & local By-Lays.

For the installation of the feeding cable carry out the following operations:

8