Hotpoint HUD 61P S manual Installation, Warning - This Appliance Must Be Earthed, Mains Connection

Models: HUD 61P S HAD60 S DSD 60 S S HUD 61G S HUD 61X S HUD 61K S

1 28
Download 28 pages 26.91 Kb
Page 5
Image 5
Installation

Installation

WARNING - THIS APPLIANCE MUST BE EARTHED.

Mains Connection

Your cooker should have been checked to ensure that the voltage corresponds with your supply voltage, this is stated on the rating plate, which is situated on the outer rear panel.

The model number and serial number are located on the front of the cooker, as shown on the Feature's page.

The cooker must be connected by a competent person such as one who is a, NICEIC registered contractor to a suitable double-pole control unit with a minimum rating of 32A and a minimum contact clearance of 3mm (applicable to newer properties, older properties where a 30A double pole control unit and a minimum contact clearance of 3mm is acceptable).

The double pole control unit should be fitted adjacent to the cooker, in accordance with IEE regulations. The control unit must be within 2 metres of but not directly above the appliance and should be easily accessible in the event of an emergency. The power supply cable should conform to B.S.6004 with a conductor size of 6mm2, minimum.

Access to the mains terminals is gained by removing the rear access cover. The mains cable must pass through the cable clamp adjacent to the terminal block. Sufficient cable should be used to allow the cooker to be pulled out for servicing.

Ensure that the mains cable is routed away from any brackets affixed to the rear panel and is not trapped to the rear wall when pushing the cooker into position between cabinets.

Levelling

Four feet are fitted which can be adjusted up or down to set the height (900mm - 930mm) and level the cooker.

The feet can be simply screwed in or out to lower or raise the cooker.

After the correct height is achieved, lock the feet into position by tightening the locking nut using an open ended spanner.

CAUTION: Some soft floor coverings may get damaged if the cooker is not moved carefully. NOTE: Ensure oven shelves are level by using a spirit level on the rod shelves.

Siting the Cooker

 

GB

The cooker is designed to fit between kitchen

cabinets spaced 600mm apart. The space either

 

 

side need only be sufficient to allow withdrawal of

 

the cooker for servicing and cleaning.

 

It can be used with cabinets one side or both as well

 

as in an angled corner setting. It can also be used

 

freestanding.

 

Adjacent side walls which project above hob level,

 

must not be nearer to the cooker than 150mm and

 

should be protected by heat resistant material. Any

 

overhanging surface or cooker hood should not be

 

nearer than 650mm.

 

Note: This appliance must NOT be fitted on a

 

platform.

 

Moving the Cooker

 

Before moving your cooker, switch off at the cooker

 

control unit, ensure that it is cool.

 

Open the grill door sufficiently to allow a comfortable

 

grip on the underside front edge of the oven roof,

 

avoiding any grill elements.

 

Radio Interference

 

This appliance conforms to EN 55014 regarding

 

suppression of radio and television interference.

 

Note: Take care in moving the cooker as it is

 

heavy. Take care to ensure that any floor

 

covering is not damaged.

 

 

 

 

 

The cooker is fitted with a safety

 

 

 

chain that must be attached to a

 

 

 

hook, secured to the wall behind the

 

 

 

appliance.

 

 

 

 

 

 

 

This appliance conforms with the following European Economic Community directives:

-2006/95/EC of 12/12/06 (Low Voltage) and subsequent modifications;

-2004/108/EC of 15/12/04 (Electromagnetic Compatibility) and subsequent modifications;

-2009/142/EC of 30/11/09 (Gas) and subsequent modifications (only for models which use gas);

-93/68/EEC of 22/07/93 and subsequent modifications.

-2002/96/EC

-1275/2008 (Stand-by/ Off Mode)

PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24

5

Page 5
Image 5
Hotpoint HUD 61P S Installation, Warning - This Appliance Must Be Earthed, Mains Connection, Levelling, Siting the Cooker