Mobile Home Installation

 

Dryer MUST be exhausted outside (outdoors, not

1

beneath the mobile home) using metal ducting

 

 

that will not support combustion. Metal ducting

 

must be 4(10.16 cm) in diameter with no

 

obstructions. Rigid metal duct is preferred.

 

If dryer is exhausted through the floor, the

2

exhaust system MUST NOT terminate beneath the

 

 

mobile home. Termination MUST be securely

 

fastened to the mobile home structure.

 

When installing a dryer into a mobile home,

3

a provision must be made for outside make-up

 

 

air. Provide an opening with a free area of at

 

least 25 square inches for introduction of outside

 

air into the dryer room.

 

Gas dryers MUST be fastened to the floor

4

using Mobile Home Installation Kit

 

 

Pub. No. 14-D346-33.

 

See the Exhaust System Requirements section

5

for other important venting information.

 

Rough-In Dimensions

6 Installation MUST conform to current Manufactured Home Construction & Safety Standard (which is a Federal Regulation Title

24 CFR—Part 32–80) or, when such standard is not applicable, with American National Standard for Mobile Homes, ANSI/NFPA No. 501B.

Correct

Do

Do

Do

Incorrect

Don’t

Don’t

Don’t

The dryer is designed under ANSI Z 21.5.1

for HOME USE only.

Safety Instructions Operating Instructions Installation

26 7/8″

(68.3 cm)

Electrical connection

2 9/16″

(6.5 cm)

13 1/2″

(34.4 cm)

3/8″ (0.96 cm) Dia.

3 3/4″ gas pipe

(9.5 cm)

REAR VIEW

47 1/2″

(120.7 cm)

Door open

90˚

435/8″

(110.7 cm)

 

 

 

 

 

 

 

 

 

 

4 3/8″

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(11.1 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36″

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(91.5 cm)

 

 

Optional

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

vent knockout

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1″ (2.54 cm)

 

27″

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(68.6 cm)

 

 

 

 

 

 

3 3/4″

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(9.5 cm)

SIDE VIEW

Instructions Troubleshooting Tips