Electrical requirements.

Read these instructions completely and carefully.

Electrical Connection Information for Electric Dryers

Safety Instructions

WARNING To reduce the risk of fire, electric shock or personal injury:

DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE.

THIS APPLIANCE MUST BE PROPERLY GROUNDED.

This dryer must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, in accordance with the

NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70.

Electrical Requirements

This dryer must be connected to a 208V or 240V individual branch circuit, protected by 30 amp circuit breakers or time-delay fuses.

Use copper conductors only.

If the electric supply does not meet the above specifications, call a licensed electrician.

NOTE: A wiring diagram is located inside the control panel.

Operating Instructions

Electrical Connection Information for Gas Dryers

WARNING To reduce the risk of fire, electric shock or personal injury:

DO NOT USE AN EXTENSION CORD OR AN ADAPTER PLUG WITH THIS APPLIANCE.

DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE THIRD GROUNDING PRONG FROM THE POWER CORD.

This dryer must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, in accordance with the

NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70.

Electrical Requirements

This dryer must be supplied with 120V, 60 Hz, and connected to an individual properly grounded branch circuit, protected by a 15 or 20 amp circuit breaker or time-delay fuse.

If the electric supply provided does not meet the above specifications, it is recommended that a licensed electrician install an approved outlet.

External Ground (if required)

An external ground wire (not provided), which meets local codes, may be added by attaching it to the green ground screw on the rear of the dryer in the upper left corner above the cord, and to grounded metal cold water pipe or other established ground.

Attach ground wire (obtain locally)

NOTE: A wiring diagram is located inside the control panel.

Installation Instructions Troubleshooting Tips

Ensure proper ground exists before use