The electrical connection to the mains must be made on the appliance. The power voltage and frequency are as indicated on the rating plate.

!THIS APPLIANCE MUST BE EARTHED. Fitting the power supply cable

Unplug the appliance before all operations, even when replacing the oven lamp.

Using the appliance without correct earthing is highly dangerous.

!After connecting the appliance to the flexible cable, tighten all the screws on the terminal board.

APPLIANCE SPECIFICATIONS

Dimensions*

width 43.5 cm

height 41 cm

 

depth 41 cm

L

N

1.Open the terminal board by inserting a screwdriver into the side tabs of the cover. Use the screwdriver as a lever by pushing it down to open the cover (see diagram)

.

2.Install the power supply cable by loosening the cable clamp screw and the three wire contact screws

L-N-Manual background.

Connect the wires to the corresponding terminals: the Blue wire to the terminal marked (N), the Brown wire to the terminal marked (L) and the Yellow/Green wire

to the terminal marked Manual background (see diagram).

Volume*

74 l

Dimensions**

height 41 cm

 

depth 41 cm

Volume**

77 l

Electrical

voltage: 230 - 240 V ~50 Hz

maximum power absorbed

connections

2600-2800 W (see data plate)

 

 

Directive 2002/40/EC on the

 

label of electric ovens.

 

Standard EN 50304

ENERGY LABEL

Declared energy consumption

 

 

for Forced convection

 

Class – heating mode:

 

ECO

 

This appliance conforms to the

 

following European Economic

 

Community directives:

 

2006/95/EEC dated 12/12/06

 

(Low Voltage) and subsequent

 

amendments – 2004/108/EEC

3.Secure the cable by fastening the clamp screw.

4.Close the cover of the terminal board.

Electrical Connection:

Voltage Frequency: see data plate

Fuse Section: 16A

Supply cable: 3x1.5mm2

You can connect your oven to the system means of a terminal board. Refer to above information for the minimal cable sections and the calibration of the protective elements according to the connection.

If the appliance is installed with a junction box, an omnipolar circuit breaker - with a minimum contact opening of 3mm - should be installed between the appliance and the mains.

Power cable supply connection to the electrical mains:

We recommend you use a power supply cable which is long enough to allow you to take the oven out of its recess in the event of maintenance operations (only use HAR - H 05 - RRF quality cables fitted with a plug conforming to the regulations in force.

The plug must be accessible at all times.

dated 15/12/04

(Electromagnetic

Compatibility) and subsequent

amendments - 93/68/EEC

dated 22/07/93 and

subsequent amendments.

2012/19/EEC and subsequent

amendments.

1275/2008 Stand-by/off mode

*Only for models with drawn rails.

**Only for models with wire rails.

PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24

6

Page 6
Image 6
Hotpoint OSHS89EDC manual GB Electrical Connection