Hotpoint RA724 6 3-WIRECONDUIT INSTALLATION, 7 4-WIRECONDUIT INSTALLATION, Replace The Wire Cover

Models: RA720 RA724

1 24
Download 24 pages 32.74 Kb
Page 18
Image 18
6 3-WIRE CONDUIT INSTALLATION

Installation Instructions

ELECTRICAL CONNECTIONS (CONT.)

6 3-WIRE CONDUIT INSTALLATION

ALoosen the 3 lower terminal screws from the terminal block. Insert the center bare wire (white/neutral) tip through the bottom center terminal block opening. On certain models, the wire will need to be inserted through the ground strap opening and then into the bottom center block opening. Insert the two side bare wire tips into the lower left and the lower right terminal block openings. Tighten the screws until the wire is firmly secure (approximately 20 inch-lbs.).

NOTE: ALUMINUM WIRING:

Aluminum building wire may be used but it must be rated for the correct amperage and voltage to make connection. Connect wires according to this Step 6 or Step 7 depending on number of wires.

Terminal NOTE: ALUMINUM WIRING: block

7 4-WIRE CONDUIT INSTALLATION

ALoosen the three lower terminal screws from the terminal block. Remove the ground screw and ground plate and retain them.

Cut and discard the ground strap. DO NOT DISCARD ANY SCREWS.

BInsert the ground bare wire tip between the range frame and the ground plate (removed earlier) and secure it in place with the ground screw (removed earlier). Insert the bare wire (white/neutral) tip through the bottom center of the terminal block opening. Insert the two side bare wire tips into the lower left and the lower right terminal block openings. Tighten the screws until the wire is firmly secure (approximately 20 inch-lbs.).

Before

Ground strap

 

Terminal

or

block

 

Cut and discard

 

the ground strap

Neutral terminal

 

Wire tips

Bracket 7 4-WIRE CONDUIT INSTALLATION

Conduit

Wire used, location and enclosure

After

Terminal block

Wire tips

Ground screw

Ground

plate

Wire used, location and enclosure8 REPLACE THE WIRE COVER (grounding Manual backgroundManual backgroundto range)

of splices, etc., must conform to good wiring practices and local codes.

BSkip to Step 8 and proceed with the installation.

Bracket

Wire used, location and enclosure

of splices, etc., must conform to good wiring practices and local codes.

CProceed to Step 8.

18

8 REPLACE THE WIRE COVER

Replace the wire cover on the range back by sliding its two lower retaining tabs into the slots and replacing the screw removed earlier. Make sure that no wires are pinched between the cover and the range back.

Page 18
Image 18
Hotpoint RA724 6 3-WIRECONDUIT INSTALLATION, 7 4-WIRECONDUIT INSTALLATION, Replace The Wire Cover, Note Aluminum Wiring