INSTALLATION INSTRUCTIONS
26
Prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure)
and the adjustment conditions are compatible. The adjustment conditions for this appliance are
stated on the data badge which is fitted behind the bottom of the main oven door seal.
This appliance is not designed to be connected to a combustion products evacuation device. It must
be installed and connected in accordance with current installation regulations. particular attention
should be given to the relevant requirements regarding ventilation.
MODEL NUMBER: S230G and DY230GCategory I2H (GB. IE)
These models are set to burn NATURAL GAS (G20) at 20 mbar ONLY and can not be used on any other
gas.
GAS SAFETY (INSTALLATION & USE) REGULATIONS
It is the law that all gas appliances are installed by competent persons in accordance with the
current edition of the above regulations. It is in your interest and that of safety to ensure compliance
with the law.
In the UK, CORGI registered installers work to safe standards of practice. The appliance must also be
installed in accordance with BS 6172. Failure to install the appliance correctly could invalidate the
warranty liability claims and could lead to prosecution.
LOCATION
The appliance may be located in a kitchen, kitchen/diner or a bed-sitting room, but not in a room
containing a bath or shower. The appliance must not be installed in a bed-sitting room of less than
20m3.
PROVISION FOR VENTILATION
The room containing the appliance should have an air supply in accordance with
BS 5440: Part 2.
The room must have an opening window or equivalent; some rooms may also require a permanent
vent. If the room has a volume between 5 and 10m3, it will require an air vent of 50cm2effective area
unless it has a door which opens directly to outside. If the room has a volume of less than 5m3, it will
require permanent air vent of 100cm2effective area. If there are other fuel burning appliances in the
same room, BS 5440: Part 2 should be consulted to determine air vent requirements.
TECHNICAL DATA
Gas connection Rp 1/2(1/2" BSP female)
Gas supply G20 at 20 mbar.
Pressure test point Grill injector
Electrical connection Flexible cord fitted with a 3 pin 13 amp plug.
230 - 240 a.c. 50HZ 3A fuse

BURNER

Grill 3.4 kW
2.4 kW
1.65 kW
150
110
095
Main Oven
Top Oven

HEAT INPUT INJECTOR