Electrical Connection

Electrical Connection

Electrical connection

The electrical connection to the mains must be made on the appliance. The power voltage and frequency are as indicated on the rating plate.

!THIS APPLIANCE MUST BE EARTHED.

Connecting the power supply cable

To open the terminal board:

Using a screwdriver, press on the tabs situated on each side of the terminal board cover.

Pull open the terminal board cover.

To connect the power supply cable, proceed as follows:

_Unscrew the cable clamp screw and the contact screws L-N-$.

Fasten the wires beneath the screwheads using the following colour scheme: Blue (N) Brown (L) Yellow-Green￿$

Fasten the power supply cable in the corresponding cable clamp and close the cover.

Electrical Connection:

Power cable supply connection to the electrical

mains:GB

We recommend you use a power supply cable which is long enough to allow you to take the oven out of its recess in the event of maintenance operations (only use HAR - H 05 - RRF quality cables fitted with a plug conforming to the regulations in force.

The plug must be accessible at all times.

Unplug the appliance before all operations, even when replacing the oven lamp.

Using the appliance without correct earthing is highly dangerous.

!After connecting the appliance to the flexible

cable, tighten all the screws on the terminal board.

DATA PLATE

width cm 37.5

Dimensions height cm 32 depth cm 41.5

Volume

lt. 50

Voltage Frequency: 230

Electrical

voltage: 230-240V ~ 50Hz maximum power absorbed

V-1+N 50Hz

Fuse Section: 16A

Supply cable: 3x1.5mm2

4 2 N L

You can connect your oven to the system means of a terminal board. Refer to above information for the minimal cable sections and the calibration of the protective elements according to the connection.

If the appliance is installed with a junction box, an omnipolar circuit breaker - with a minimum contact opening of 3mm - should be installed between the appliance and the mains.

connections

2800W-3000W

Directive 2002/40/EC on the label of electric ovens.

Standard EN 50304

Energy consumption for Natural

ENERGY LABEL convection – heating mode: Convection mode.

Declared energy consumption for Forced convection Class – heating

mode: The plug must be accessible at all times. Baking.

This appliance conforms to the following European Economic Community directives:

-2006/95/EEC of 12/12/06 (Low Voltage) and subsequent amendments;

- 89/336/EEC of 03/05/89 (Electromagnetic Compatibility) and subsequent amendments;

- 93/68/EEC of 22/07/93 and subsequent amendments.