IP Routing Features

Configuring IRDP

[ minadvertinterval < seconds > ]

This parameter specifies the minimum amount of time the routing switch can wait between sending Router Advertisements. Default: three-fourths (0.75) the value of the maxadvertinterval parameter.

If you change the maxadvertinterval parameter, the software automatically adjusts the minadvertinterval parameter to be three-fourths the new value of the maxadvertinterval parameter. If you want to override the automatically configured value, you can specify an interval from 1 to the current value of the maxadvertinterval parameter.

[preference < number >]

This parameter specifies the IRDP preference level of this routing switch. If a host receives Router Advertisements from multiple routers, the host selects the router interface that sent the message with the highest preference as the host's default gateway. The valid range is -4294967296 to 4294967295. Default: 0.

Displaying IRDP Information

To display IRDP information, enter the following command from any CLI level:

ProCurve# show ip irdp

 

 

 

 

 

Status and Counters - ICMP Router Discovery Protocol

 

 

Global Status : Disabled

 

 

 

 

 

VLAN Name

Status

Advertising

Min int Max int

Holdtime Preference

 

 

Address

(sec)

(sec)

(sec)

 

-------------- -------- ------------

-------

-------

-------- -----------

DEFAULT_VLAN

Enabled

multicast

450

600

1800

0

VLAN20

Enabled

multicast

450

600

1800

0

VLAN30

Enabled

multicast

450

600

1800

0

 

 

 

 

 

 

 

Figure 7-9. Example of Displaying IRDP Information

7-25