Getting Started

Monitoring Status

General Alarm Indicators

Loss No data transitions at the input port.

Pattern Loss The received data pattern is not in synchronization

 

with the internally generated reference data.

Errors

A measured error has occurred. The indicator will

 

remain lit for 100 ms.

PDH / DSn Alarm Indicators

These are active when a PDH / DSn signal is received

AIS

The All Ones AIS signal is detectable in the presence of

 

a 1 in 10-3error rate.

Frame Loss

Frame alignment lost or out of alignment condition.

M/Frame Loss Multiframe alignment lost.

Remote Alarm Remote alarm, x-bit or yellow alarm bit is set.

Remote M/

Frame Alarm Remote Multiframe Alarm bit is set.

ATM Alarm Indicators

These are active when an ATM signal is received.

VP Alarm

Virtual Path AIS or FERF has been detected.

VC Alarm

Virtual Channel AIS or FERF has been detected.

Loss of Cell

 

Sync

Cell Sync Loss has been detected.

Selected Cell

The selected cell has not been received.Selected cell not

Not RX

 

received.

Jitter Alarm Indicators

Jitter Unlock The jitter receiver has lost phase lock. Jitter measurement is suspended until lock is regained.

Jitter Hits A jitter hit has been detected.

28