Getting Started
Monitoring Status
General Alarm Indicators
Loss No data transitions at the input port.
Pattern Loss The received data pattern is not in synchronization
| with the internally generated reference data. |
Errors | A measured error has occurred. The indicator will |
| remain lit for 100 ms. |
PDH / DSn Alarm Indicators
These are active when a PDH / DSn signal is received
AIS | The All Ones AIS signal is detectable in the presence of |
| a 1 in |
Frame Loss | Frame alignment lost or out of alignment condition. |
M/Frame Loss Multiframe alignment lost.
Remote Alarm Remote alarm,
Remote M/
Frame Alarm Remote Multiframe Alarm bit is set.
ATM Alarm Indicators
These are active when an ATM signal is received.
VP Alarm | Virtual Path AIS or FERF has been detected. |
VC Alarm | Virtual Channel AIS or FERF has been detected. |
Loss of Cell |
|
Sync | Cell Sync Loss has been detected. |
Selected Cell | The selected cell has not been received.Selected cell not |
Not RX | |
| received. |
Jitter Alarm Indicators
Jitter Unlock The jitter receiver has lost phase lock. Jitter measurement is suspended until lock is regained.
Jitter Hits A jitter hit has been detected.